FS3G160-48GL-90 DC Single Inlet Centrifugal Blower 160mm 48V 652 m3/h

FS3G160-48GL-90

Nominal Voltage VDC 48
Current draw A 3.125±10%
Speed(RPM) min-1  1850±5%
Power consumption W 150±10%
Max. Air Flow CFM / m3 /H 383.5/651.7
Max. Static Pressure In.wg /Pa 2.48/620

50pcs

Brand:
FANOVA
Spu:
FS3G160-48GL-90
  • Overview
  • Recommended Products

Brief Description

The FS3G160-48GL-90 is a 48VDC single-inlet centrifugal blower engineered for direct integration into telecom -48VDC power plants and DCIM-monitored equipment racks, where its 160mm galvanized-steel impeller and die-cast aluminum housing deliver 383.5 CFM (651.7 m3/h) at 2.48 in.wg (620 Pa) static pressure from a compact 92mm rotor. Operating across a 36 to 57VDC input window, the BLDC DC92 motor draws 3.125 A and 150 W at 1850 RPM, allowing the blower to ride through battery-float and equalize cycles without an intermediate AC/DC converter. Speed is commanded by 0-10VDC analog or PWM input, with FG tach output for closed-loop fan-speed verification, and the control board can be swapped to Modbus RS485 for full DCIM telemetry without changing the mechanical envelope. Motor windings are Class F insulated with Class B rise under locked-rotor protection, and the dual ball-bearing system is rated for 70,000 hours at 40 C ambient, supporting seven-year continuous duty in outside-plant cabinets. The galvanized steel impeller resists abrasion from dust-laden airflow and holds balance at 1850 RPM, while the die-cast aluminum endcap damps structure-borne vibration and provides a stable motor mounting face. Typical installations include telecom base-station heat exchangers, rack-mounted rectifier cooling, remote radio head cabinets, and industrial DC microgrid enclosures. The blower is CE and RoHS compliant and is built under ISO 9001 quality control, with a 20AWG 220mm flying lead for power and signal connections. For design engineers standardizing on -48VDC plant power, the FS3G160-48GL-90 replaces AC-input blowers and their transformers with a single high-efficiency DC air mover.

Product Specification

The FS3G160-48GL-90 is built around a single-inlet centrifugal impeller of 160mm diameter, fabricated from galvanized steel sheet and formed into a forward-curved blade set that produces 383.5 CFM (651.7 m3/h) free delivery and a maximum static pressure of 2.48 in.wg (620 Pa). The steel construction is selected for telecom and industrial duty: the zinc coating resists corrosion in humid cabinet air, the blade edges tolerate dust and lint without the erosion seen on thinner polymer wheels, and the all-metal rotor maintains dynamic balance through the 1850 RPM operating point and repeated thermal cycling. The impeller is mounted on a 92mm rotor diameter BLDC DC92 motor, an electronically commutated outrunner-style design with integrated Hall sensing and a six-step commutation controller. At 48VDC nominal the motor draws 3.125 A and delivers 150 W of shaft power; the input range of 36 to 57VDC covers the full -48VDC telecom plant window including battery discharge and equalize conditions, so the blower can be fed directly from the DC bus without a dedicated AC/DC supply. Speed control is via a 0-10VDC analog input or a 25 kHz PWM input, selectable at the connector, and the FG tach output provides two pulses per revolution for stall detection and DCIM logging; the control board can be factory-configured for Modbus RS485 communication, giving register-level access to speed command, actual RPM, current and fault status for integration with building or rack management systems. Electrical protection includes locked-rotor current limiting, under-voltage lockout below 36VDC, and over-voltage clamp above 57VDC. The motor is Class F insulated with Class B temperature rise, and the winding is vacuum-impregnated to resist vibration. Bearings are preloaded dual ball bearings with a calculated L10 life of 70,000 hours at 40 C ambient, mounted in a die-cast aluminum endcap that also serves as the heat path from the motor and damps structure-borne noise; the housing is finished with a conversion coating for cabinet-grade corrosion resistance. The blower emits 71 dB(A) at one meter at full speed, and the inlet is machined for a standard 160mm duct flange. Electrical interface is a 220mm 20AWG flying lead with separate power and signal conductors, terminated to the customer's harness specification. The unit is CE and RoHS compliant and manufactured under an ISO 9001 quality system with 100 percent end-of-line run-in and hipot testing.

Nominal Date

DC Single Inlet Centrifugal Blower FS3G160-48GL-90 DC Single Inlet Centrifugal Blower product photo
Type FS3G160-48GL-90
Model BLDCDC92

 

Nominal Voltage VDC 48
Voltage range VDC 36~57
Current draw A 3.125±10%
Speed(RPM) min-1  1850±5%
Power consumption W 150±10%
Sound Pressure Level dB(A) 71±5%
Max. Air Flow CFM / m3 /H 383.5/651.7
Max. Static Pressure In.wg /Pa 2.48/620
Insulation class ~ Class B
Degree of protection ~ IP44
Control Input ~ 0~10VDC / PWM
Signal Output ~ FG (Tach output )

Connection diagram

FS3G160-48GL-90 wiring and connection diagram

Remarks:

Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized

Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel

Product drawing

FS3G160-48GL-90 dimension drawing for 160mm fan

Aerodynamic Performance Charts

FS3G160-48GL-90 airflow and static pressure performance curve

Test condition:

Ⅰ.The test data is obtained under the specified environment conditions and installation mode

Ⅱ.Input Voltage---Operating voltage

Ⅲ.Temperature---Room temperature 25℃

Ⅴ.Humidity---65%RH

Safety Requirements

Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off

Ⅱ.Do not plug or unplug the fan lead plug when the fan is running

Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury

Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out

Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds

Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product

Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer

Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading

Advantages:

1. High Efficiency: The FS3G160-48GL-90 delivers 651.7 m3/h at 620 Pa while drawing only 150W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.

2. Industrial-Grade Impeller: The 160mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.

3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).

4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.

5. Easy Installation and Maintenance: Compact 160mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.

FAQ

Q1:What kind of payments do you support?

A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping

Q2.Will you provide samples?

A2: Sample is available and can be delivered within 10days

Q3:How can I choose a more suitable model?

A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.

Q4:How can I place the order?

A4:  Usually quote you within 24 hours  after  we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.

Q5:About transportation

A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive. 

Q6:How long is the warranty period?

A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.

Related models in the same series

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000