FANOVA FS3G180-2AGL-90 Passes ERP 2026 Fan Energy Efficiency Compliance Test

Aug 17, 2026

Suzhou, China — FANOVA MOTOR announces that its FS3G180-2AGL-90 EC single-inlet centrifugal fan has successfully passed the ERP 2026 fan energy efficiency compliance test conducted in accordance with Commission Regulation (EU) 2024/1834.

The test, performed on 14 August 2026, verified that the fan meets the minimum energy efficiency requirements specified in Annex II, Point 1 of the regulation, which applies to motor-driven fans with an electric input power between 125 W and 500 kW. The measured fan efficiency at the Best Efficiency Point (BEP) reached 45.87%, exceeding the required minimum of 34.28% — a margin of 11.6 percentage points. After applying the correction factors specified in Annex III (Cp × Cc × Cguard), the corrected efficiency reaches 54.09%.

What Is ERP 2026?

ERP 2026 refers to Commission Regulation (EU) 2024/1834, published on 4 July 2024, which sets ecodesign requirements for fans driven by motors with an electric input power between 125 W and 500 kW. The regulation:

  • Replaces the earlier Regulation (EU) No 327/2011
  • Applies to fans at their best efficiency point (BEP), including fans integrated into other products
  • Defines minimum fan efficiency grades (N values) per fan type, measurement category, and efficiency category
  • Requires quantified fan efficiency information at part load to help system designers optimise energy use
  • Mandates the availability of spare parts and end-of-life information, supporting circular economy objectives

For the FS3G180-2AGL-90, the applicable efficiency grade N is 52 (forward curved centrifugal fan, measurement category A/C, static efficiency category, Pe < 5 kW).

Test Summary

Parameter Value
Model FS3G180-2AGL-90
Fan type EC single-inlet centrifugal fan
Report No. FBEP2608002
Test date 2026-08-14
Motor type BLEC92
Rated voltage 230 VAC
Rated power 0.206 kW
Rated speed 1600 RPM
Impeller diameter 180 mm
Impeller material Galvanized steel sheet
VSD equipped Yes (integrated)
Test standard EN ISO 5801:2017
Supply 230 VAC / 50 Hz

Best Efficiency Point (BEP) Data

Parameter Value
Speed 2412 RPM
Volume flow rate (qv) 524.8 m³/h
Fan static pressure (Δps) 646 Pa
Electric input power (Pe) 0.2053 kW
Measured fan efficiency (η) 45.87%

Full Test Points

Point Current (A) Speed (RPM) Pe (W) Qv (m³/h) Δps (Pa) Efficiency
Pt 1 0.60 2523 80 0 614 0.00%
Pt 2 0.851 2523 116.8 232.4 560 30.95%
Pt 3 (BEP) 1.434 2412 205.3 524.8 646 45.87%
Pt 4 1.435 2077 205.3 712.5 470 45.31%
Pt 5 1.435 1810 205.5 831.4 258 29.00%
Pt 6 1.436 1587 205.8 938.2 105 13.30%
Pt 7 1.436 1428 206.0 1013.0 16 2.19%
Pt 8 1.40 1600 200 1023.6 0 0.00%

Compliance Calculation

Minimum Efficiency Requirement (Annex II, Point 1)

For Pe < 10 kW, the minimum fan efficiency is:

η_min = 4.56 × ln(Pe) − 10.5 + N   [%]

With Pe = 0.2053 kW and N = 52:

η_min = 4.56 × ln(0.2053) − 10.5 + 52
      = 4.56 × (−1.583) − 10.5 + 52
      ≈ 34.28%

Correction Factors (Annex III, Point 6.1)

The measured fan efficiency is corrected as:

η = Cp × Cc × Cguard × (Pu / Pe)

where Pu = qv × Δp is the fan gas power at BEP.

Factor Value Basis
Cp (power conversion) 1.0 AC supply, no <100 V DC converter
Cc (part-load compensation) 1.1792 VSD equipped, Pe < 5 kW: 1 + 0.0812 × Pe⁻⁰·⁵
Cguard (guard compensation) 1.0 No guard
η = 1.0 × 1.1792 × 1.0 × 0.4587 = 54.09%

Verdict

Measured η at BEP
45.87%
≥ 34.28% · Compliant
Corrected η
54.09%
≥ 34.28% · Compliant

The fan meets the ERP 2026 minimum fan efficiency requirements of Annex II, Point 1.

Why This Matters for System Designers

The FS3G180-2AGL-90 delivers a measured efficiency 11.6 percentage points above the regulatory minimum, providing:

  • Lower energy cost: higher efficiency at BEP means less electrical input per unit of delivered airflow
  • Design headroom: the margin over η_min protects against unit-to-unit variation and verification tolerances (93% of declared value at BEP)
  • Simplified compliance documentation: the test report supports the Internal Design Control conformity assessment under Annex IV of Directive 2009/125/EC (ESPR (EU) 2024/1781)
  • Future-proofing: compliance is verified now, ahead of the regulation's application dates

About FANOVA MOTOR

FANOVA MOTOR (Fanova (Suzhou) Motor Technology Co., Ltd.) is a Suzhou-based manufacturer of EC (electronically commutated) motors and fans, serving HVAC, data centre cooling, energy storage, cleanroom, and industrial ventilation applications worldwide. The company offers 8 fan series covering 363 models with impeller diameters from 108 mm to 630 mm, all built on in-house EC motor technology with efficiencies above 90% and 30–50% energy savings versus conventional AC solutions.

FANOVA products are CE certified, ISO 9001:2015 certified, and now ERP 2026 compliant ahead of the regulatory deadline. For the FS3G180-2AGL-90 or other models in the FS3G single-inlet centrifugal fan range, contact: