FS3G180-48GL-90 DC Single Inlet Centrifugal Blower 180mm 48V 970 m3/h

FS3G180-48GL-90

Nominal Voltage VDC 48
Current draw A 4.2±10%
Speed(RPM) min-1  1600±5%
Power consumption W 200±10%
Max. Air Flow CFM / m3 /H 570.85/970
Max. Static Pressure In.wg /Pa 2.68/670

50pcs

Brand:
FANOVA
Spu:
FS3G180-48GL-90
  • Overview
  • Recommended Products

Brief Description

Telecom and DC power engineers get a purpose-built 48VDC centrifugal blower with the FS3G180-48GL-90, a single-inlet machine whose galvanized steel impeller and die-cast aluminum housing shrug off heat, dust and continuous duty in -48VDC plant rooms. Its two superpowers are native 48VDC operation across a 36 to 57VDC window (no AC/DC conversion stage, so it drops straight onto rectifier, battery and DC bus rails) and a 180 mm steel impeller that delivers 970 m3/h (570.85 CFM) at free air while holding 670 Pa (2.68 in.wg) of static pressure for filter-loaded cabinets. The brushless DC motor (92 mm rotor, BLDC DC92 platform) draws 4.2 A and 200 W at 1600 RPM, producing 70 dB(A) at one meter, and is controlled by either 0-10VDC or PWM input with an FG tach output for DCIM speed and fault monitoring. Electrical protection and insulation are built to the usual industrial fan standard, and the dual ball-bearing system is rated for 70,000 hours at 40 C ambient, giving years of service between interventions. Typical installations include telecom shelters, outdoor cabinets, rectifier bays, battery rooms, switchgear enclosures, railway signaling racks and renewable-energy power conversion cabinets. The FS3G180-48GL-90 carries CE and RoHS certification and is manufactured under ISO 9001, with Modbus485 communication available as an alternative to the standard analog/PWM control.

Product Specification

The FS3G180-48GL-90 is a single-inlet centrifugal blower built around a 180 mm diameter impeller fabricated from galvanized steel sheet. The impeller uses a forward-curved, multi-blade configuration that produces high pressure at moderate tip speed; the galvanized coating resists corrosion and abrasion in dusty or humid cabinet air, and the steel construction tolerates temperatures that would deform plastic wheels. Each impeller is balanced after assembly to keep vibration low at the 1600 RPM design point. The inlet ring and outer housing are die-cast aluminum, giving a rigid, dimensionally stable structure that damps motor noise and resists distortion under continuous thermal cycling. Air enters axially through the single inlet and discharges at 90 degrees through a rectangular outlet, the classic form factor for ducted cabinet cooling and plenum-mounted heat exchangers. At free air the unit moves 570.85 CFM (970 m3/h); at maximum static pressure it develops 2.68 in.wg (670 Pa), which is enough head to push air through dense filters, long duct runs or multiple discharge outlets without stalling. The fan is driven by a 92 mm brushless DC motor designed for the 48VDC rail. It accepts any supply from 36 to 57VDC, so it is compatible with nominal -48VDC telecom plants, 48V battery banks and 48V DC microgrids without a separate converter. At 48VDC the motor draws 4.2 A and delivers 200 W of shaft power at 1600 RPM. The motor uses electronic commutation with Hall-effect sensing, which eliminates brush wear and gives a service life independent of commutator condition. Speed is set by a 0-10VDC analog input or a PWM duty-cycle signal, selectable at the connector; a frequency-generator (FG) output provides a tachometer pulse proportional to speed, allowing a supervisory controller or DCIM platform to monitor RPM and detect stalls or bearing degradation. The control interface can be re-specified with Modbus485 communication for installations that prefer a digital bus; the standard build ships with analog/PWM control. Electrical connection is made through a 262 mm flying lead of 20AWG cable, with separate conductors for power, control input and FG output. The motor winding is insulated to Class F and the assembly is protected against over-current, locked-rotor and reverse-polarity conditions at the drive level. Bearings are pre-lubricated dual ball bearings rated for 70,000 hours at 40 C, selected for low acoustic emission and stable running at the 70 dB(A) sound pressure level measured at one meter. The die-cast aluminum housing also acts as a heat sink for the motor electronics, keeping drive temperatures in check in sealed enclosures. The FS3G180-48GL-90 is CE and RoHS compliant and produced in an ISO 9001-certified facility, with each unit hipot tested and performance sampled before shipment. It is intended for telecom shelters, outdoor electronic cabinets, rectifier and battery rooms, industrial control panels, railway signaling racks and power-electronics cooling, where 48VDC is the native bus and reliable, monitorable airflow is the requirement.

Nominal Date

DC Single Inlet Centrifugal Blower FS3G180-48GL-90 DC Single Inlet Centrifugal Blower product photo
Type FS3G180-48GL-90
Model BLDCDC92

 

Nominal Voltage VDC 48
Voltage range VDC 36~57
Current draw A 4.2±10%
Speed(RPM) min-1  1600±5%
Power consumption W 200±10%
Sound Pressure Level dB(A) 70±5%
Max. Air Flow CFM / m3 /H 570.85/970
Max. Static Pressure In.wg /Pa 2.68/670
Insulation class ~ Class B
Degree of protection ~ IP44
Control Input ~ 0~10VDC / PWM
Signal Output ~ FG (Tach output )

Connection diagram

FS3G180-48GL-90 wiring and connection diagram

Remarks:

Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized

Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel

Product drawing

FS3G180-48GL-90 dimension drawing for 180mm fan

Aerodynamic Performance Charts

FS3G180-48GL-90 airflow and static pressure performance curve

Test condition:

Ⅰ.The test data is obtained under the specified environment conditions and installation mode

Ⅱ.Input Voltage---Operating voltage

Ⅲ.Temperature---Room temperature 25℃

Ⅴ.Humidity---65%RH

Safety Requirements

Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off

Ⅱ.Do not plug or unplug the fan lead plug when the fan is running

Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury

Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out

Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds

Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product

Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer

Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading

Advantages:

1. High Efficiency: The FS3G180-48GL-90 delivers 970 m3/h at 670 Pa while drawing only 200W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.

2. Industrial-Grade Impeller: The 180mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.

3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).

4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.

5. Easy Installation and Maintenance: Compact 180mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.

FAQ

Q1:What kind of payments do you support?

A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping

Q2.Will you provide samples?

A2: Sample is available and can be delivered within 10days

Q3:How can I choose a more suitable model?

A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.

Q4:How can I place the order?

A4:  Usually quote you within 24 hours  after  we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.

Q5:About transportation

A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive. 

Q6:How long is the warranty period?

A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.

Related models in the same series

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000