| Nominal Voltage | VAC | 230 |
| Current draw | A | 0.5±10% |
| Speed(RPM) | min-1 | 2800±5% |
| Power consumption | W | 50±10% |
| Max. Air Flow | CFM / m3 /H | 165.84/281.8 |
| Max. Static Pressure | In.wg /Pa | 1.56/390 |
50pcs
Quiet enough to hold a conversation beside, the FS3G108-2AGL-70 is a 108 mm single-inlet centrifugal blower that keeps its 64 dB(A) sound floor while moving up to 281.8 m3/h and 390 Pa. That combination of low noise and 230VAC EC72 brushless drive makes it a direct drop-in for AC blowers in air handlers, lab fume hoods and office ventilation units, where the only change contractors notice is a lower electricity bill. The integrated drive accepts anything from 184 to 277VAC, so the same part number serves 230V nominal grids and 277V North American lighting-panel feeds without a step-down transformer. At 2800 RPM the forward-curved galvanized steel impeller draws just 50 W and 0.5 A, well inside the sub-100 W class, letting a single 20AWG three-wire harness carry power, 0-10VDC or PWM speed command and an FG tach signal back to the controller. The die-cast aluminum endcap holds rotor and stator alignment through thermal cycling, and the EC72 electronics bring over-voltage, locked-rotor and thermal protection plus Class B insulation as standard. Bearing life is rated for continuous duty, and the optional Modbus485 protocol swap turns the blower into a networked node for building management systems. Typical installations include cleanroom FFU stacks, medical exhaust, refrigeration condenser drawers, telecom cabinets and commercial ventilation boxes; the unit carries CE and RoHS marking and is produced under the Suzhou ISO 9001 quality system.
The FS3G108-2AGL-70 is built around a 108 mm diameter single-inlet centrifugal impeller stamped from galvanized steel sheet, with forward-curved blades locked into a riveted hub and shroud so the wheel holds its balance at 2800 RPM. Galvanized steel was specified rather than molded plastic because it resists elevated airstream temperatures, shrugs off the abrasive dust found in condenser and filtration duty, and will not creep or soften over years of continuous rotation. Each wheel is dynamically balanced before assembly, then mounted on a 72 mm rotor shaft supported by pre-lubricated ball bearings selected for long L10 life in horizontal or vertical mounting. The impeller runs inside a scroll formed from die-cast aluminum, a material chosen for its dimensional stability and its ability to sink heat away from the motor compartment; the result is a compact blower that delivers 165.84 CFM (281.8 m3/h) at free air and 1.56 in.wg (390 Pa) at shutoff, a pressure capability that lets the unit push through dense filter media and long rectangular duct runs without the airflow collapse typical of axial fans. Drive comes from the EC72, a brushless DC motor with an integrated commutating inverter mounted on the motor body. The EC72 accepts a universal 184 to 277VAC input, rectifies it internally and produces the three-phase waveform that spins the rotor, so no external VFD or transformer is needed. Electrical draw is 0.5 A and 50 W at the design point, and power factor correction keeps line harmonics low enough for multi-unit installations on a shared branch. Speed is set by a 0-10VDC analog signal or a PWM input, both on the same control lead, and the drive reports rotational speed through an FG tachometer output that a host controller can read to confirm airflow or detect a stalled wheel. The standard control scheme can be re-flashed to Modbus485 communications at the factory, giving full register access to speed setpoint, actual RPM, fault status and cumulative run hours for DCIM and BMS integration. Protection inside the EC72 covers over-voltage, under-voltage, locked rotor, over-temperature and short-circuit events, with automatic restart after a fault clears; motor insulation is Class B. The electrical interface is a 159 mm flying lead of 20AWG conductors, color-coded for line, neutral, control and tach, and terminated for direct connection to a terminal block or controller header. The blower is CE marked and RoHS compliant, and every unit is hipot tested, run-in and sound-checked at the Suzhou plant under an ISO 9001 quality system before packing. Mounting is by the aluminum endcap flange in any orientation, and the low 64 dB(A) sound pressure at one meter suits the unit to occupied spaces such as offices, laboratories, clinics and hotel ventilation risers.
| EC Single Inlet Centrifugal Blower | ![]() |
|
| Type | FS3G108-2AGL-70 | |
| Model | BLDCEC72 | |
| Nominal Voltage | VAC | 230 |
| Voltage range | VAC | 184~277 |
| Current draw | A | 0.5±10% |
| Speed(RPM) | min-1 | 2800±5% |
| Power consumption | W | 50±10% |
| Sound Pressure Level | dB(A) | 64±5% |
| Max. Air Flow | CFM / m3 /H | 165.84/281.8 |
| Max. Static Pressure | In.wg /Pa | 1.56/390 |
| Insulation class | ~ | Class B |
| Degree of protection | ~ | IP44 |
| Control Input | ~ | 0~10VDC / PWM |
| Signal Output | ~ | FG (Tach output ) |

Remarks:
Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized
Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel


Test condition:
Ⅰ.The test data is obtained under the specified environment conditions and installation mode
Ⅱ.Input Voltage---Operating voltage
Ⅲ.Temperature---Room temperature 25℃
Ⅴ.Humidity---65%RH
Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off
Ⅱ.Do not plug or unplug the fan lead plug when the fan is running
Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury
Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out
Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds
Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product
Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer
Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading
1. High Efficiency: The FS3G108-2AGL-70 delivers 281.8 m3/h at 390 Pa while drawing only 50W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.
2. Industrial-Grade Impeller: The 108mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.
3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).
4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.
5. Easy Installation and Maintenance: Compact 108mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.
Q1:What kind of payments do you support?
A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping
Q2.Will you provide samples?
A2: Sample is available and can be delivered within 10days
Q3:How can I choose a more suitable model?
A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.
Q4:How can I place the order?
A4: Usually quote you within 24 hours after we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.
Q5:About transportation
A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive.
Q6:How long is the warranty period?
A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.