FK3G220-24PL-95 DC Plug Fan 220mm 24V 1246 m3/h

FK3G220-24PL-95

Nominal Voltage VDC 24
Current draw A 6.0±10%
Speed(RPM) min-1  3500±5%
Power consumption W 144±10%
Max. Air Flow CFM / m3 /H 733.57/1246.5
Max. Static Pressure In.wg /Pa 3.6/900

50pcs

Brand:
FANOVA
Spu:
FK3G220-24PL-95
  • Overview
  • Recommended Products
Brief Description

When a 24 VDC power budget must still deliver serious pressure, the FK3G220-24PL-95 plug fan turns low-voltage safety into a high-static-pressure asset. Its backward-curved impeller, molded from glass-fiber reinforced propylene, generates up to 900 Pa (3.6 in. wg) while moving as much as 1246.5 m3/h (733.57 CFM) at 3500 RPM, so a single compact 220 mm unit can replace a pair of lower-pressure fans in tight ductwork, dense filter banks and multi-outlet plenums. The BLDCDC92 brushless DC motor draws 6.0 A from a 16-28 VDC range and consumes 144 W, making the fan directly compatible with 24 V battery banks, solar-charged off-grid cabinets and mobile equipment where mains voltage is unavailable or undesirable. Speed is commanded through a 0-10 V analog or PWM interface, letting the system trim airflow to actual demand instead of running flat out. Class F insulation and locked-rotor, over-voltage and reverse-polarity protection safeguard the electronics, while the 92 mm rotor spins on pre-lubricated ball bearings rated for 40,000 hours at 40 degrees C. At 74 dB(A) the fan suits enclosure cooling, telecom and renewable-energy cabinets, air handling units and industrial ventilation. The die-cast aluminum endcap and 20AWG, 500 mm flying lead simplify installation, and the unit carries CE and RoHS compliance with options for UL recognition.

Product Specification

The FK3G220-24PL-95 is a backward-curved centrifugal plug fan built around a 220 mm diameter impeller injection-molded from glass-fiber reinforced propylene. The composite wheel uses a hub-and-shroud construction with a carefully staggered blade count that reduces tonal noise while maintaining a steep pressure curve; the material combines low mass with resistance to moisture, mild chemicals and UV exposure, and it will not corrode in coastal or humid installations. Rotation is counter-clockwise viewed from the inlet, and the wheel is dynamically balanced to ISO 1940 G6.3 before assembly, keeping vibration low across the full 3500 RPM operating speed. The impeller is mounted directly on the motor shaft, eliminating belt losses and alignment issues. The fan delivers a maximum airflow of 1246.5 m3/h (733.57 CFM) and a maximum static pressure of 900 Pa (3.6 in. wg); the steep backward-curved characteristic means the fan holds pressure well when filters load or duct runs are long, making it suitable for high-resistance air paths and multi-branch distribution. The BLDCDC92 brushless DC motor is a 92 mm rotor design with integrated commutation electronics, operating from 16 to 28 VDC and drawing 6.0 A at 24 VDC for 144 W input. Speed control is available through a 0-10 VDC analog input or a 25 kHz PWM signal, with a tachometer output for speed feedback and an optional alarm output for system monitoring; soft-start limits inrush current and extends relay life. Electrical protection includes locked-rotor current limiting, over-voltage and under-voltage cutout, and reverse-polarity protection, so miswiring during commissioning does not destroy the drive. Insulation is Class F, and the motor is designed for a dielectric strength of 1500 VAC for one minute. The shaft runs in two pre-lubricated, double-shielded ball bearings with an L10 life of 40,000 hours at 40 degrees C ambient, and the bearing seats are machined to tight tolerances to control end play. The die-cast aluminum endcap provides a rigid mounting flange, acts as a heat spreader for the electronics and resists vibration; the assembly is rated for continuous operation from -20 to +60 degrees C. A 500 mm, 20AWG multi-conductor cable exits the housing for power and control connections, with color-coded leads for 24 VDC, ground, 0-10 V/PWM, tach and alarm. The fan is CE marked and RoHS compliant, with UL recognition available on request. Each unit is hipot tested, run-in and sound-checked before packing; typical sound pressure at one meter is 74 dB(A) at free delivery, and the fan can be mounted in any orientation. Target applications include 24 VDC enclosure cooling, solar and off-grid cabinets, telecom shelters, air handling units, laboratory extraction and industrial ventilation where high pressure and low-voltage safety are both required.

Nominal Date
DC Plug Fan image.png
Type FK3G220-24PL-95
Model BLDCDC92

 

Nominal Voltage VDC 24
Voltage range VDC 16~28
Current draw A 6.0±10%
Speed(RPM) min-1  3500±5%
Power consumption W 144±10%
Sound Pressure Level dB(A) 74±5%
Max. Air Flow CFM / m3 /H 733.57/1246.5
Max. Static Pressure In.wg /Pa 3.6/900
Insulation class ~ Class B
Degree of protection ~ IP44
Control Input ~ 0~10VDC / PWM
Signal Output ~ FG (Tach output )
Connection diagram
image.png

Remarks:

Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized

Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel

Product drawing
image.png
Aerodynamic Performance Charts
image.png

Test condition:

Ⅰ.The test data is obtained under the specified environment conditions and installation mode

Ⅱ.Input Voltage---Operating voltage

Ⅲ.Temperature---Room temperature 25℃

Ⅴ.Humidity---65%RH

Safety Requirements

Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off

Ⅱ.Do not plug or unplug the fan lead plug when the fan is running

Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury

Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out

Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds

Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product

Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer

Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading

Advantages:

1. High Efficiency: The FK3G220-24PL-95 delivers 1246.5 m3/h at 900 Pa while drawing only 144W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.

2. Industrial-Grade Impeller: The 220mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.

3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).

4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.

5. Easy Installation and Maintenance: Compact 220mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.

FAQ

Q1:What kind of payments do you support?

A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping

Q2.Will you provide samples?

A2: Sample is available and can be delivered within 10days

Q3:How can I choose a more suitable model?

A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.

Q4:How can I place the order?

A4:  Usually quote you within 24 hours  after  we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.

Q5:About transportation

A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive. 

Q6:How long is the warranty period?

A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000