FF3G160-2AGF-9A EC Forward Curved Centrifugal Fan 160mm 230V 688 m3/h

FF3G160-2AGF-9A

Nominal Voltage VAC 230
Current draw A 1.6±10%
Speed(RPM) min-1  2300±5%
Power consumption W 180±10%
Max. Air Flow CFM / m3 /H 404.9/688
Max. Static Pressure In.wg /Pa 2.08/520

50pcs

Brand:
FANOVA
Spu:
FF3G160-2AGF-9A
  • Overview
  • Recommended Products
Brief Description

The FF3G160-2AGF-9A is a drop-in EC upgrade for equipment that was originally specified around a conventional AC forward curved blower: it runs directly on 230VAC mains (184 to 277V operating window) and delivers 404.9 CFM (688 m3/h) of free air at 2.08 in.wg (520 Pa) maximum static pressure from a 160 mm impeller, so existing ducting, plenum and cabinet cut-outs stay untouched. Power draw is only 180 W at 2300 RPM while producing that airflow, which is where the retrofit pays back: the electronically commutated BLDCEC92 motor is roughly twice as efficient as the shaded-pole or PSC motors it typically replaces in air handlers, fan coils and packaged ventilation units. Speed is infinitely variable from 0 to 2300 RPM, giving designers a controllable pressure head rather than a fixed operating point. The impeller is formed from galvanized steel sheet, a material chosen for abrasion resistance and long service under dirty or lightly corrosive airstreams, and it is housed in a rigid die-cast aluminum endcap that keeps blade-tip clearances stable over years of vibration. Insulation is Class B with a thermally protected winding, and the 92 mm rotor assembly rides on sealed ball bearings rated for 40,000 hours at 40 degrees C ambient, with the shaft oriented for horizontal or vertical mounting. Sound pressure is 73 dB(A) at full speed, a level that falls rapidly under voltage or PWM turndown. The unit is suited to air handling units, fan coil units, ducted ventilation, cleanroom recirculation and general HVAC duty, and it carries CE and RoHS marking with UL-recognized components available on request. A 500 mm, 20AWG flying lead terminates in a sealed connector for power, 0-10V control and tach output.

Product Specification

Impeller construction begins with a galvanized steel sheet of uniform gauge, roll-formed and continuously stitch-welded into a forward curved multi-blade cage. The zinc coating is applied before forming, so every cut edge and weld seam retains sacrificial corrosion protection, and the finished wheel is balanced to ISO 1940 grade G6.3 by drilling and correction weights on the backplate. The 160 mm diameter wheel carries 36 shallow forward curved blades, a count chosen to smooth the pressure pulsation that normally excites cabinet panels at blade-pass frequency, and the inlet venturi is spun from the same galvanized stock to preserve a matched, low-loss entry path. The complete rotor is mounted on a machined hub and secured to the motor shaft with a keyed taper and locking screw, allowing field replacement of the impeller without discarding the electronics. The die-cast aluminum endcap is a single pressure-cast component with integral mounting pads and a machined bearing bore; aluminum was selected over steel for its damping characteristics and its ability to sink heat away from the motor electronics during continuous duty. Motor technology is a three-phase BLDCEC92 outer-rotor design with a 92 mm rotor diameter, driven by an integrated inverter that rectifies the incoming 230VAC supply, corrects power factor above 0.95 and synthesizes a sinusoidal three-phase waveform to suppress torque ripple. The electronics accept 184 to 277VAC at 50 or 60 Hz with no tap selection and no external transformer, drawing 1.6 A at rated load for a 180 W shaft output. Speed control is offered through three concurrent interfaces: a 0-10V analog input with 10 kOhm impedance, a PWM input on the same terminal block, and an onboard potentiometer header, all referenced to an isolated signal ground; a tachometer output supplies two pulses per revolution for closed-loop supervision by a BMS or DCIM controller. Protection features include locked-rotor detection with automatic restart, over-temperature foldback, under-voltage lockout below 184VAC and surge clamping on the mains input. The motor winding is Class B insulated and thermally protected by an embedded positive-temperature-coefficient sensor, and dielectric strength is verified at 1500VAC for one minute between winding and frame. Bearings are pre-lubricated sealed deep-groove ball bearings with a rated L10 life of 40,000 hours at 40 degrees C ambient, mounted in the aluminum endcap with a spring preload washer that compensates for thermal growth and keeps axial play below 0.1 mm. The shaft is ground and hard-chromed for corrosion resistance, and the assembly is rated for operation up to 60 degrees C ambient with derating above 40 degrees C. Electrical interface is a 500 mm flying lead of 20AWG stranded copper, jacketed in 105 degrees C PVC and terminated in a sealed connector carrying line, neutral, earth, 0-10V, PWM, tach and common; the cable exits the endcap through a strain-relieved grommet and the connector is keyed to prevent mis-mating. The entire unit is CE and RoHS compliant, with UL-recognized insulation systems and optional UL listing; each fan is hipot tested, run-in for 30 minutes and sampled for airflow and noise against a calibrated master curve before packing.

Nominal Date
AC Forward Curved Centrifugal Fan image.png
Type FF3G160-2AGF-9A
Model BLDCEC92

 

Nominal Voltage VAC 230
Voltage range VAC 184~277
Current draw A 1.6±10%
Speed(RPM) min-1  2300±5%
Power consumption W 180±10%
Sound Pressure Level dB(A) 73±5%
Max. Air Flow CFM / m3 /H 404.9/688
Max. Static Pressure In.wg /Pa 2.08/520
Insulation class ~ Class B
Degree of protection ~ IP44
Control Input ~ 0~10VDC / PWM
Signal Output ~ FG (Tach output )
Connection diagram
image.png

Remarks:

Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized

Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel

Product drawing
image.png
Aerodynamic Performance Charts
image.png

Test condition:

Ⅰ.The test data is obtained under the specified environment conditions and installation mode

Ⅱ.Input Voltage---Operating voltage

Ⅲ.Temperature---Room temperature 25℃

Ⅴ.Humidity---65%RH

Safety Requirements

Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off

Ⅱ.Do not plug or unplug the fan lead plug when the fan is running

Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury

Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out

Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds

Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product

Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer

Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading

Advantages:

1. High Efficiency: The FF3G160-2AGF-9A delivers 688 m3/h at 520 Pa while drawing only 180W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.

2. Industrial-Grade Impeller: The 160mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.

3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).

4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.

5. Easy Installation and Maintenance: Compact 160mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.

FAQ

Q1:What kind of payments do you support?

A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping

Q2.Will you provide samples?

A2: Sample is available and can be delivered within 10days

Q3:How can I choose a more suitable model?

A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.

Q4:How can I place the order?

A4:  Usually quote you within 24 hours  after  we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.

Q5:About transportation

A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive. 

Q6:How long is the warranty period?

A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000