FK3G175-48LH-7F
| Nominal Voltage | VDC | 48 |
| Current draw | A | 2.0±10% |
| Speed(RPM) | min-1 | 4250±5% |
| Power consumption | W | 96±10% |
| Max. Air Flow | CFM / m3 /H | 939.4/798.1 |
| Max. Static Pressure | In.wg /Pa | 2.93/731 |
50pcs
The FK3G175-48LH-7F is a 48VDC backward-curved centrifugal plug fan built for telecom -48VDC bus architectures, where its 96 W power draw and 731 Pa maximum static pressure let a single compact unit replace multiple lower-pressure fans inside densely packed equipment cabinets. Its 175 mm glass-fiber reinforced propylene impeller is molded in one piece for dynamic balance at 4250 RPM, while the die-cast aluminum endcap carries the BLDCDC72 brushless DC motor and acts as a structural heat sink that keeps winding temperatures stable during continuous DCIM-monitored operation. Air performance reaches 939.4 CFM (798.1 m3/h) at free delivery and holds pressure against long duct runs, high-density filter banks and multi-outlet plenums, so the fan suits filter walls and exhaust paths that would stall a conventional axial unit. Speed is commanded over a 0-10 VDC analog interface with PWM and tach feedback options, and the wide 36 to 57VDC input range rides through battery-float and rectifier transients without an external converter. Electrical protection includes locked-rotor and over-current shutdown, reverse-polarity tolerance and Class B insulation, and the dual ball-bearing system is rated for 70,000 hours at 40 degrees C to match telecom life-cycle expectations. At 73 dB(A) the acoustic signature stays within typical shelter and outdoor-cabinet limits, and the 20AWG 500 mm flying lead terminates directly at the controller terminal block. Applications include telecom rectifier shelves, outdoor base-station enclosures, DCIM-managed server racks, railway signaling cabinets, photovoltaic inverter cooling and industrial DC microgrid ventilation. The fan carries CE and RoHS declarations and is produced under ISO 9001 quality management.
The impeller of the FK3G175-48LH-7F is a 175 mm diameter backward-curved centrifugal wheel injection-molded from glass-fiber reinforced propylene, a compound selected for its stiffness-to-weight ratio, resistance to ultraviolet exposure and chemical attack, and its ability to hold blade geometry after thousands of thermal cycles. The wheel uses a multi-blade backward-curved profile in which each blade is swept and cambered to accelerate air radially while suppressing separation at the trailing edge; the hub and shroud are molded as a single homogeneous part, eliminating the riveted joints that can loosen under vibration. Each impeller is dynamically balanced to ISO 1940 G6.3 before assembly, and the resulting low rotating mass limits bearing load and start-up inrush. The die-cast aluminum endcap forms the stationary housing and motor mount in one rigid casting; its ribs stiffen the scroll transition and its thermal mass conducts heat away from the stator, holding winding temperature rise within Class B limits across the full 36 to 57VDC input window. Drive is provided by a BLDCDC72 three-phase brushless DC motor with integrated commutation electronics, hall-effect rotor position sensing and sinusoidal current shaping for low torque ripple and smooth acceleration from standstill. At the nominal 48VDC operating point the fan draws 2.0 A and consumes 96 W while turning 4250 RPM, producing a maximum free-air flow of 939.4 CFM (798.1 m3/h) and a maximum static pressure of 2.93 in.wg (731 Pa); the steep pressure curve lets the unit hold delivery against long ducts, dense filter media and multi-outlet manifolds. Speed control accepts a 0-10VDC analog command, a 25 kHz PWM duty signal or an onboard potentiometer, with an open-collector tachometer output for RPM verification and alarm signaling; the control harness is separate from the power lead so that low-level signals are not corrupted by motor current. The power interface is a 20AWG, 500 mm flying lead with stripped and tinned ends for direct termination at a controller or DIN terminal block, and the input is protected against reverse polarity, locked rotor, over-current and over-temperature, with automatic restart after fault clearance. Rotor support is provided by two pre-lubricated dual-shield ball bearings selected for low noise and long life, rated at 70,000 hours L10 at 40 degrees C ambient and lubricated for life so that no maintenance interval is required. The fan operates over an ambient range of -20 to +60 degrees C and at 73 dB(A) sound pressure at one meter, keeping it within the limits of outdoor telecom cabinets and shelter installations. The assembly is RoHS compliant and carries a CE declaration of conformity for electromagnetic compatibility and low-voltage directives, and production follows an ISO 9001 quality system with 100 percent end-of-line run-in, hipot and balance verification. Typical installations include -48VDC rectifier shelves, remote radio head enclosures, DCIM-instrumented data racks, photovoltaic inverter cooling, railway signaling cabinets and industrial DC microgrid equipment, where the combination of high static pressure, low power and native 48VDC operation removes the need for AC inverters and their conversion losses.
| DC Plug Fan | ![]() |
|
| Type | FK3G175-48LH-7F | |
| Model | BLDCDC72 | |
| Nominal Voltage | VDC | 48 |
| Voltage range | VDC | 36~57 |
| Current draw | A | 2.0±10% |
| Speed(RPM) | min-1 | 4250±5% |
| Power consumption | W | 96±10% |
| Sound Pressure Level | dB(A) | 73±5% |
| Max. Air Flow | CFM / m3 /H | 939.4/798.1 |
| Max. Static Pressure | In.wg /Pa | 2.93/731 |
| Insulation class | ~ | Class B |
| Degree of protection | ~ | IP44 |
| Control Input | ~ | 0~10VDC / PWM |
| Signal Output | ~ | FG (Tach output ) |

Remarks:
Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized
Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel


Test condition:
Ⅰ.The test data is obtained under the specified environment conditions and installation mode
Ⅱ.Input Voltage---Operating voltage
Ⅲ.Temperature---Room temperature 25℃
Ⅴ.Humidity---65%RH
Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off
Ⅱ.Do not plug or unplug the fan lead plug when the fan is running
Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury
Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out
Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds
Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product
Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer
Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading
1. High Efficiency: The FK3G175-48LH-7F delivers 798.1 m3/h at 731 Pa while drawing only 96W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.
2. Industrial-Grade Impeller: The 175mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.
3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).
4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.
5. Easy Installation and Maintenance: Compact 175mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.
Q1:What kind of payments do you support?
A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping
Q2.Will you provide samples?
A2: Sample is available and can be delivered within 10days
Q3:How can I choose a more suitable model?
A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.
Q4:How can I place the order?
A4: Usually quote you within 24 hours after we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.
Q5:About transportation
A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive.
Q6:How long is the warranty period?
A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.