FD3G146-2APV-90
| Nominal Voltage | VAC | 230 |
| Current draw | A | 1.5±10% |
| Speed(RPM) | min-1 | 1850±5% |
| Power consumption | W | 220±10% |
| Max. Air Flow | CFM / m3 /H | 691.1/1174.4 |
| Max. Static Pressure | In.wg /Pa | 2.42/606 |
50pcs
When a 230VAC installation needs serious pressure behind the airflow, the FD3G146-2APV-90 answers with 606 Pa of static pressure and 1174.4 m3/h of free delivery from a single compact dual inlet platform. This dual inlet centrifugal blower pairs a 146 mm glass-fiber reinforced polypropylene impeller with a 92 mm rotor and a BLDCEC92 electronically commutated motor rated 220 W at 1850 RPM, drawing 1.5 A from a wide 184-270VAC envelope so it rides out mains sags without tripping. The EC drive makes it a drop-in electrical replacement for AC blowers: wire 230VAC line and neutral, apply a 0-10V signal or PWM command, and modulate airflow steplessly instead of switching taps or throttling with dampers. Because the impeller is molded from glass-fiber reinforced propylene, it shrugs off moisture, mild chemical attack and the fatigue that eventually cracks welded metal wheels, while keeping rotating mass low enough for quick, quiet acceleration. The die-cast aluminum endcap carries the bearing seats and motor flange, holding shaft alignment through continuous duty and conducting heat away from the windings. Insulation is Class F with thermal protection built into the electronics, and the ball bearing set is specified for 40,000 hours at 40 degrees C ambient, giving OEMs a maintenance-free service window. At 69.6 dB(A) the unit suits air handling cabinets, cleanroom make-up air, heat recovery ventilators, telecom enclosures and light industrial exhaust where predictable pressure matters more than showroom silence. The blower is CE and RoHS compliant and backed by FANOVA's Suzhou manufacturing and OEM/ODM engineering support. Typical configurations include dual outlet ducting for supply and return, speed feedback via tach output, and custom cable lengths on request.
The FD3G146-2APV-90 is built around a double-inlet centrifugal impeller measuring 146 mm in diameter and molded from propylene compounded with glass fiber reinforcement. Each of the two inlet eyes feeds a bank of forward-curved blades, and the twin volute discharges merge into a single rectangular outlet so one motorized wheel delivers the airflow of two smaller single-inlet fans. Blade count and curvature are tuned for the 1850 RPM duty point, producing 1174.4 m3/h (691.1 CFM) at free air and 606 Pa (2.42 in.wg) at shutoff, a pressure capability that supports long duct runs, dense filter banks and multi-outlet plenums without staging a second blower. The glass-fiber loading raises tensile and creep resistance well above unfilled plastic, so blade tips hold their profile after years of continuous rotation, and the material resists hydrolysis in humid airstreams where steel wheels would corrode.
The rotor, 92 mm in diameter, is driven by a BLDCEC92 electronically commutated motor with permanent magnets on the rotor and a three-phase stator switched by integrated power electronics. This architecture eliminates brushes, slip rings and capacitor-run starting circuits, and it delivers efficiency that a shaded-pole or PSC motor of the same frame cannot approach, which is how the unit holds 220 W at full load while remaining controllable across its entire speed band. Speed is commanded through a 0-10V analog input or a PWM interface, with tachometer feedback available for closed-loop airflow or pressure control in the host system. The motor accepts 230VAC nominal with an operating window of 184 to 270VAC at 50 or 60 Hz, so it tolerates utility undervoltage and overvoltage excursions common on long feeders and generator-backed supplies. Full-load current is 1.5 A.
Mechanical construction centers on a die-cast aluminum endcap that houses the bearing bores and motor mounting flange in one rigid casting. Aluminum was chosen over stamped steel because the casting holds bearing centers concentric under belt-free direct drive, damps vibration transmitted into the housing, and conducts heat from the motor electronics to the airstream. The shaft runs in a pair of pre-lubricated ball bearings rated for an L10 life of 40,000 hours at 40 degrees C ambient, and the bearing stack is preloaded to suppress axial play and the low-frequency rumble that follows it. Sound pressure at full speed is 69.6 dB(A) measured at one meter, a figure dominated by blade-pass tone rather than motor noise; mounting the blower on resilient isolators and avoiding abrupt duct transitions keeps installed levels close to the test value.
The electrical interface terminates in a factory-fitted cable of 20AWG conductors, sized for the 1.5 A running current with margin for inrush and for runs up to several meters inside an equipment cabinet. Conductors carry line, neutral, protective earth, the 0-10V or PWM control pair and, where specified, tach output; the flying lead is stripped and tinned for terminal-block landing or can be ordered with a connector. Insulation is Class F, and the onboard electronics include locked-rotor and overtemperature protection that folds back or shuts down the drive rather than letting the windings cook. Dielectric strength and creepage distances follow the applicable EN 60335 and EN 61800 requirements for the 230VAC class.
Every unit is functionally tested at the Suzhou plant for speed accuracy, current draw, pressure and vibration before packing, and the design carries CE and RoHS declarations. FANOVA supplies the FD3G146-2APV-90 as a standard catalog blower or as an OEM/ODM variant with modified cable lengths, connector types, control curves, mounting brackets and labeling, supported by sample runs, airflow-pressure data and engineering liaison from prototype through series production.
| AC Dual Inlet Centrifugal Blower | ![]() |
|
| Type | FD3G146-2APV-90 | |
| Model | BLDCEC92 | |
| Nominal Voltage | VAC | 230 |
| Voltage range | VAC | 184~270 |
| Current draw | A | 1.5±10% |
| Speed(RPM) | min-1 | 1850±5% |
| Power consumption | W | 220±10% |
| Sound Pressure Level | dB(A) | 69.6±5% |
| Max. Air Flow | CFM / m3 /H | 691.1/1174.4 |
| Max. Static Pressure | In.wg /Pa | 2.42/606 |
| Insulation class | ~ | Class B |
| Degree of protection | ~ | IP44 |
| Control Input | ~ | 0~10VDC / PWM |
| Signal Output | ~ | FG (Tach output ) |

Remarks:
Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized
Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel


Test condition:
Ⅰ.The test data is obtained under the specified environment conditions and installation mode
Ⅱ.Input Voltage---Operating voltage
Ⅲ.Temperature---Room temperature 25℃
Ⅴ.Humidity---65%RH
Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off
Ⅱ.Do not plug or unplug the fan lead plug when the fan is running
Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury
Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out
Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds
Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product
Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer
Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading
1. High Efficiency: The FD3G146-2APV-90 delivers 1174.4 m3/h at 606 Pa while drawing only 220W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.
2. Industrial-Grade Impeller: The 146mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.
3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).
4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.
5. Easy Installation and Maintenance: Compact 146mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.
Q1:What kind of payments do you support?
A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping
Q2.Will you provide samples?
A2: Sample is available and can be delivered within 10days
Q3:How can I choose a more suitable model?
A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.
Q4:How can I place the order?
A4: Usually quote you within 24 hours after we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.
Q5:About transportation
A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive.
Q6:How long is the warranty period?
A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.