FB3G150-1APL-70 EC Backward Curved Centrifugal Fan 150mm 115V 455 m3/h

FB3G150-1APL-70

Nominal Voltage VAC 115
Current draw A 0.6±10%
Speed(RPM) min-1  3550±5%
Power consumption W 35±10%
Max. Air Flow CFM / m3 /H 268/455.4
Max. Static Pressure In.wg /Pa 1.42/355

50pcs

Brand:
FANOVA
Spu:
FB3G150-1APL-70
  • Overview
  • Recommended Products
Brief Description

The FB3G150-1APL-70 turns the volume down on centrifugal ventilation: at just 63 dB(A) this 150 mm backward curved impeller runs below the level of ordinary conversation, making it the rare EC fan you can install directly beside people. Its second advantage is plug-and-play simplicity for North America and Japan: a 115VAC nominal winding that accepts anything from 92 to 138 volts, so it connects straight to a standard wall supply with no step-down transformer, no external PSU and no wiring rework. The BLDCEC72 electronically commutated motor draws only 0.6 A and 35 W while delivering up to 268 CFM (455.4 m3/h) of free airflow and 1.42 in.wg (355 Pa) of static pressure at 3550 RPM, an efficiency that keeps 24/7 duty cycles cheap to run. Speed is trimmed through the integrated EC control interface rather than by voltage, so airflow can be matched to the duty point without the hum and heat of triac dimming. The impeller is molded from glass-fiber reinforced propylene, light enough to spin up quickly and chemically resistant, and it is carried in a die-cast aluminum housing that holds tolerances and damps vibration. Class F insulation with Class B rise, locked-rotor and reverse-polarity protection, and a 20AWG 500 mm cable complete the electrical package, while the dual ball-bearing system is rated for 70,000 hours at 40 degrees C. Typical installations are medical and laboratory analyzers, office and classroom air handling, cleanroom FFU modules, display cases and light commercial HRV/ERV units, and the fan carries CE and RoHS declarations with UL-compliant construction on request.

Product Specification

The FB3G150-1APL-70 is a 150 mm diameter backward curved centrifugal fan built around a molded impeller of glass-fiber reinforced propylene. The wheel uses a dense array of deeply curved backward inclined blades that sweep air outward and rearward, a geometry chosen because it self-limits absorbed power as resistance rises: the motor cannot be overloaded by a blocked duct, and the steep pressure curve holds flow steady through filters and long runs. Glass-fiber loading stiffens each blade so tip deflection stays negligible even at the 3550 RPM design point, and the polypropylene base resists most dilute acids, alkalis and cleaning agents, which suits wash-down-adjacent equipment and outdoor air paths. The impeller is dynamically balanced in two planes after molding and mounts on a steel hub keyed to the motor shaft, with the whole rotor assembly spinning inside a die-cast aluminum endcap and venturi. Aluminum was selected over stamped steel because its dimensional stability keeps the tip clearance uniform over the full temperature range, cutting the blade-passing noise that off-center impellers produce. The motor is a BLDCEC72 three-phase electronically commutated unit with an integrated inverter board, rated 115VAC nominal over an operating window of 92 to 138 volts at 50/60 Hz, drawing 0.6 A and 35 W. Permanent magnets in the rotor and sinusoidal commutation give smooth torque with none of the cogging ripple of a comparable AC induction motor, and the onboard control accepts a 0-10 VDC or PWM speed signal so airflow can be set anywhere from minimum to the 3550 RPM maximum. At full speed the fan moves 268 CFM (455.4 m3/h) at free air and develops 1.42 in.wg (355 Pa) at shutoff, a duty point that covers HEPA pre-filters, dense coil banks and multi-outlet plenums in compact air handlers. Electrical protection includes locked-rotor current limiting, reverse-polarity and over-voltage clamping, soft start to avoid inrush trips on shared 115 V circuits, and Class F insulation with Class B temperature rise for long thermal margin. The motor rides on two pre-lubricated dual ball bearings rated 70,000 hours at 40 degrees C ambient, seated in rubber-isolated mounts that keep structure-borne vibration out of the enclosure. Connection is a 500 mm lead of 20AWG cable, stripped and tinned for direct terminal-block wiring, with color-coded conductors for line, neutral, ground and control. The fan is RoHS compliant, carries a CE declaration, and is built to UL-compliant creepage and clearance practice for 115 V class appliances on request; every unit is hipot tested and burn-in run before packing. Mounting is by the four tapped bosses on the aluminum endcap in any orientation, and the 150 mm frame fits standard 150 mm fan cutouts for drop-in replacement of AC centrifugal blowers.

Nominal Date
AC Backward Curved Centrifugal Fan image.png
Type FB3G150-1APL-70
Model BLDCEC72

 

Nominal Voltage VAC 115
Voltage range VAC 92~138
Current draw A 0.6±10%
Speed(RPM) min-1  3550±5%
Power consumption W 35±10%
Sound Pressure Level dB(A) 63±5%
Max. Air Flow CFM / m3 /H 268/455.4
Max. Static Pressure In.wg /Pa 1.42/355
Insulation class ~ Class B
Degree of protection ~ IP44
Control Input ~ 0~10VDC / PWM
Signal Output ~ FG (Tach output )
Connection diagram
image.png

Remarks:

Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized

Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel

Product drawing
image.png
Aerodynamic Performance Charts
image.png

Test condition:

Ⅰ.The test data is obtained under the specified environment conditions and installation mode

Ⅱ.Input Voltage---Operating voltage

Ⅲ.Temperature---Room temperature 25℃

Ⅴ.Humidity---65%RH

Safety Requirements

Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off

Ⅱ.Do not plug or unplug the fan lead plug when the fan is running

Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury

Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out

Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds

Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product

Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer

Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading

Advantages:

1. High Efficiency: The FB3G150-1APL-70 delivers 455.4 m3/h at 355 Pa while drawing only 35W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.

2. Industrial-Grade Impeller: The 150mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.

3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).

4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.

5. Easy Installation and Maintenance: Compact 150mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.

FAQ

Q1:What kind of payments do you support?

A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping

Q2.Will you provide samples?

A2: Sample is available and can be delivered within 10days

Q3:How can I choose a more suitable model?

A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.

Q4:How can I place the order?

A4:  Usually quote you within 24 hours  after  we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.

Q5:About transportation

A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive. 

Q6:How long is the warranty period?

A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000