FD3G146-110GL-90L
| Nominal Voltage | VDC | 110 |
| Current draw | A | 1.8±10% |
| Speed(RPM) | min-1 | 1700±5% |
| Power consumption | W | 198±10% |
| Max. Air Flow | CFM / m3 /H | 890.9/1513.9 |
| Max. Static Pressure | In.wg /Pa | 1.31/328 |
50pcs
When a single compact blower must move as much air as two or three smaller fans, the FD3G146-110GL-90L answers with 1513.9 m3/h (890.9 CFM) of dual-inlet airflow from one 146 mm frame. Its second strength is the 110VDC bus architecture: at 110 volts DC the unit draws only 1.8 A to deliver 198 W, so distribution wiring stays thin, I2R losses stay low and a single rectifier or battery bank can feed a whole rack of blowers across an industrial DC microgrid. This model pairs a 92 mm rotor BLDCDC92 brushless DC motor with a 146 mm double-width, double-inlet impeller pressed from galvanized steel sheet, and the die-cast aluminum endcap and housing carry the bearing loads while radiating heat away from the windings. Speed is set at 1700 RPM by a 0-10V analog signal or PWM input, giving stepless modulation from standstill to full flow without a separate VFD. Electrical protection covers locked-rotor and over-current shutdown, insulation is Class F with a Class B rise limit, and the dual ball bearings are rated for 40,000 hours L10 at 40 degrees C ambient. The combination of steel impeller, high static pressure of 328 Pa (1.31 in.wg) and heavy-duty 198 W output suits air-handling units, cleanroom recirculation, telecom shelter cooling, battery energy storage cabinets and dust-collection plenums. Each blower is CE and RoHS marked, and production runs are backed by FANOVA's ISO 9001 quality system. For OEM programs, airflow curves, cable lengths and mounting flanges can be customized.
The FD3G146-110GL-90L is a dual-inlet centrifugal blower built around a 146 mm diameter impeller with a 92 mm rotor hub, which gives the wheel a wide, double-width blade span that draws air in from both sides of the die-cast aluminum housing. The impeller is fabricated from galvanized steel sheet rather than molded plastic: the zinc coating resists corrosion in humid or mildly chemical-laden airstreams, the steel holds its blade geometry at 1700 RPM without creep, and the metal wheel tolerates higher operating temperatures than PA66 or ABS. Multi-vane forward-curved blades, welded or riveted to the backplate and shroud, generate the pressure characteristic that lets this blower reach 328 Pa (1.31 in.wg) static pressure while still delivering 1513.9 m3/h (890.9 CFM) at free air. The motor is a BLDCDC92 brushless DC machine rated 110VDC nominal with an operating range of roughly 60 to 130VDC, drawing 1.8 A and 198 W at the design point. Commutation is electronic, so there are no brushes to replace and no commutator arcing; an integrated driver stage converts the DC bus into three-phase stator currents through Hall-effect rotor position feedback. Speed control accepts a 0-10V analog reference or a 25 kHz PWM duty signal on the control leads, and a tachometer output reports actual RPM for closed-loop system control. The blower starts and reverses direction without inrush surges, which keeps the 110VDC distribution bus stable when several units switch on together. Electrical interfaces are brought out on a 20AWG cable, 209 mm long, with flying leads for power and control; connectors and longer harnesses are available to order. Protection features include locked-rotor shutdown with automatic restart attempts, over-current limiting, under-voltage lockout and thermal fold-back, all handled inside the motor electronics. Insulation is Class F (155 degrees C) with a Class B temperature rise limit, and the windings see a dielectric withstand test before shipment. Mechanically, the shaft runs in two pre-lubricated dual ball bearings rated 40,000 hours L10 life at 40 degrees C, sized for the radial loads the wide impeller imposes. The die-cast aluminum endcap and housing act as a structural spine and a heat sink, holding bearing alignment and pulling motor heat into the airstream. Sound pressure is held to 68 dB(A) at one meter, a level dominated by the blade-pass tone rather than motor noise, and the steel wheel's stiffness keeps that tone clean. The blower is CE marked and RoHS compliant, and every unit is run-tested for current, speed, airflow and vibration before packing under FANOVA's ISO 9001 quality system.
| DC Dual Inlet Centrifugal Blower | ![]() |
|
| Type | FD3G146-110GL-90L | |
| Model | BLDCDC92 | |
| Nominal Voltage | VDC | 110 |
| Voltage range | VDC | 60 |
| Current draw | A | 1.8±10% |
| Speed(RPM) | min-1 | 1700±5% |
| Power consumption | W | 198±10% |
| Sound Pressure Level | dB(A) | 68±5% |
| Max. Air Flow | CFM / m3 /H | 890.9/1513.9 |
| Max. Static Pressure | In.wg /Pa | 1.31/328 |
| Insulation class | ~ | Class B |
| Degree of protection | ~ | IP44 |
| Control Input | ~ | 0~10VDC / PWM |
| Signal Output | ~ | FG (Tach output ) |

Remarks:
Ⅰ. Standard cable length Refer to the figure below. The length of cable can be customized
Ⅱ. Conventional mode is 0-10V/PWM control, can optionally replace the communication protocol, detailed communication protocol, please contact technical personnel


Test condition:
Ⅰ.The test data is obtained under the specified environment conditions and installation mode
Ⅱ.Input Voltage---Operating voltage
Ⅲ.Temperature---Room temperature 25℃
Ⅴ.Humidity---65%RH
Ⅰ.When taking out the fan, do not directly lift the fan lead wire. If the lead wire is excessively stressed, the internal welding part may fall off
Ⅱ.Do not plug or unplug the fan lead plug when the fan is running
Ⅲ.If the fan does not work after starting, do not touch the impeller, rotor, or other parts, professional technical personnel are required to inspect the fan to prevent sudden start of the fan from causing hand or other personal injury
Ⅳ.The power line and control line of the fan cannot be connected in reverse, otherwise it will burn out
Ⅴ.Because of the soft start characteristics of the fan, to prevent personal injury, do not touch the impeller or other parts of the fan during powered on or running at low speeds
Ⅵ.The fan needs to be operated and used under the guidance of professional personnel to prevent children from coming into touch this product
Ⅶ.If the power line is worn or damaged, it needs to be returned to the manufacturer for repair or be replaced under the guidance of the manufacturer
Ⅷ.As a part of the fan, it is not recommended to use the motor alone when there is no impeller or loading
1. High Efficiency: The FD3G146-110GL-90L delivers 1513.9 m3/h at 328 Pa while drawing only 198W, achieving 30-40% energy savings over equivalent AC fans through FANOVA's BLDC motor technology.
2. Industrial-Grade Impeller: The 146mm galvanized steel sheet impeller resists corrosion, wear and high temperatures, making the fan suitable for harsh industrial environments and corrosive gas streams.
3. Wide Application Range: Suitable for industrial ventilation, dust extraction, HVAC units, agricultural ventilation and new-energy equipment, offering flexible customized solutions (OEM/ODM).
4. Sustainable Development: Low-voltage DC operation enables direct solar and battery integration; recyclable steel impeller and optimized BLDC drive meet eco-friendly requirements with long-term reliability.
5. Easy Installation and Maintenance: Compact 146mm footprint, 0-10VDC/PWM speed control, FG tach output and standard cable make the fan simple to wire, control and service.
Q1:What kind of payments do you support?
A1: For sample order, 100% payment in advance; For batch order, 30% in advance and 70% will be paid before shipping
Q2.Will you provide samples?
A2: Sample is available and can be delivered within 10days
Q3:How can I choose a more suitable model?
A3: We need the information like fan type, quantity, size, material, voltage, air flow and static pressure.
Q4:How can I place the order?
A4: Usually quote you within 24 hours after we get your inquiry. First sign the PI,pay deposit,then we will arrange the production.After finished production need you pay balance. Finally we will ship the Goods.
Q5:About transportation
A5: All available shipping ways could be applied, express shipping, air or sea. Appointed shipping company or our own forwarders all could be used in shipment. Full-way tracking the cargos for you before the goods arrive.
Q6:How long is the warranty period?
A6: We currently offer 3-year quality guarantee for our own products, and in response to current product problems, our company provides line support, and some customers have been able to improve their products.